Why does current shift from voltage?

Installation, principle and limits

Sinusoidal steady state, ideal components. Series R-L load with a parallel capacitor on a source with no internal impedance. U is the RMS value; the peak is √2 U. X = 2πfL; I = U/Z for the load; P = RI²; Q = XI² − 2πfCU²; S = UI. φ is positive when current lags. Harmonics, saturation, capacitor losses and switch-on transients are not simulated. The 0.95 threshold is an exercise target, not a contractual requirement.

Wikipedia · power factor ↗